Sir, As a beginner of FRIC I am facing some difficulties to implement it. The downloaded FRIC code has been added to my pile soil friction model and trying to validate with the hypo plasticity model. I am confused about the input of hypo plastic properties. When i am giving the properties on User defined material properties i am getting the error as umat is not attached. Does this “FRIC .for” already included the umat.
Regarding FRIC : As a beginner
Related Articles
-
Intergranular strain concept modification
Piotr Kowalczyk||Constitutive Modelling|1 |Views 4,132
Hi all Just a short question on the modification of the intergranular strain concept proposed by Wegener & Herle (2014) to limit strain accumulation. In terms of the numerical implementation […] -
Automatic calibration software ExCalibre has been launched
David Mašín||Constitutive Modelling|0 |Views 4,407
On behalf of the team of developers I am happy to announce that, after more than four years of development and testing, ExCalibre has just been launched. ExCalibre is a […] -
MatLab m.file
Ala Aljorany||Constitutive Modelling|6 |Views 5,381
Hi everyone, I’m trying to simulate a triaxial test by using Matlab, adopting the sand hypoplasticity model with strain softening but so far couldn’t succeed. Would anyone help me with […] -
Sanisand umat with BV problem
Luis Aviles||Constitutive Modelling|0 |Views 3,865
Hi, Does someone know if sanisand implementation has been used in a boundary value problem for slope? do you have any references? Thanks very much! -
Htypoplastic Model in Miidas GTS NX
Kassem Dib||Constitutive Modelling|6 |Views 2,313
Hello.. I am defining the hypoplastic parameters for Karlsruhe sand (found in a paper) using MIDAS GTS NX. In the software the a requesting (in addition of parameters) the number […] -
Error: permission to access files denied (Hypoplasticity in PLAXIS)
Katharina Fechtner||Constitutive Modelling|7 |Views 5,953
Hello, I am trying to implement the dll for hypoplasticity in Plaxis 3D. It runs through both the Initial Phase and a Nil Step. However, when it calculates about 20 […] -
Subroutine of SANISAND model
Pooja Patil||Constitutive Modelling|16 |Views 5,206
I am trying use sanisand subroutine posted in this website. But it is not working. Getting no values for field variable in the odb. I think i am missing something. […] -
Hypoplastcity sand model
Pooja Patil||Constitutive Modelling|11 |Views 4,436
Not able to run the subroutine ……..error is coming ……UMAT: illegal (negative) actual void ratio detected Can anybody help
Search SoilModels Website
Recent posts
- Degradation ( disturbance ) of hypoplastic clay 23.4.2024
- Degradation ( disturbance ) of hypoplastic clay 23.4.2024
- Paper of Coulomb, C. A. (1773) 15.4.2024
- ABAQUS UMAT of hypoplastic clay model 6.4.2024
- Prague Geotechnical Days 2024 “Geotechnical monitoring” and 30th jubilee Prague Geotechnical Lecture by prof. Eduardo Alonso 5.4.2024
- UMAT for Creep-SCLAY model. 1.3.2024
- Cyclic tests with Triax element test driver 14.2.2024
- SUMMER SCHOOL ‘Numerical Modelling in Geotechnical Engineering’, Innsbruck – July 22nd-26th, 2024 1.2.2024
- COURSE IN SOIL MODELING – NTNU, Trondheim – October 14th to 18th, 2024 21.12.2023
- MSE walls design in Plaxis 11.12.2023
- sand liquefaction modelling in Anura3D 8.12.2023
- BCV bentonite experimental and modelling datasets 14.11.2023
Recent Comments
- Ramon Varghese on SANISAND for FLAC3D Download
- Akhtyar Gul Shirzoi on ABAQUS UMAT of hypoplastic clay model
- KHA DIDJA on Animating Soil Models
- Jh Xue on Undrained Tests with Clay Hypoplasticity Intergranular
- Zhentao Liu on Problem in simulating CPT using SANISAND04
- Gertraud Medicus on ABAQUS UMAT of hypoplastic clay model
- Chen Zhiming on Download Package of Charles University Implementation of High Cycle Accumulation Model
- Konstantinos Chatzis on Cyclic tests with Triax element test driver
- Abhay Pratap Singh on Cyclic tests with Triax element test driver
- Giovanni Ciardi on Cyclic tests with Triax element test driver
- Konstantinos Chatzis on Cyclic tests with Triax element test driver
- Ismail Khan on Cyclic tests with Triax element test driver
- Kanika Lamba on Cyclic tests with Triax element test driver
- Arie Koot on How to model the settlement in soil due to water drawdown.
- Konstantinos Chatzis on Cyclic tests with Triax element test driver
- Jose Duque on Cyclic tests with Triax element test driver
- MohamadReza Kamali on How to model the settlement in soil due to water drawdown.
- Leo Alibert on MSE walls design in Plaxis
Dear Arun,
I will try to answer all your questions and a bit more.
1. The file Fric_HPvW is only the contact model which have a coding interface using the UMAT as a constitutive driver for the contact. But there is no UMAT attached. What you can do is to simply copy the UMAT.for for the hypoplastic model and attach it to the FRIC_HPvW.for file.
2. The abbreviation Fric_HPvW refers to the Hypoplastic model from von Wolffersdorff that is for granular media. Keep this in mind if you want to model fine-grained interfaces.
3. Please have a look to the UMAT documentation, because the second property is a numerical cohesion value. You have to follow the input for the properties.
4. You have to use the exact amount of parameters described in the documentation for the FRIC otherwise the subroutine will interrupt and you must specify the amount of state variables.
5. The state variables must also be defined for the UMAT use.